Description:
Unit 4 is powered by 2- 60 Series 475 BHP Detroit Diesel engines for the
power supply of the "on demand" hydraulic system and the tri-plex pump
packages via Allison HT750DR transmissions.
Tri-plex pumps are MSI 600 equipped with 3 ½" plungers for a maximum
working pressure of 10,400 psi. With this configuration, this unit will be
able to provide > 500 HHP total. Maximum pump rate at low pressure will be
> 10 bpm.
This unit has dual over pressure safety features utilizing a manual pop off
set to 10,500 psi. It also has an electronic shut down that can be set to a
desired pressure and will drop the engines to idle and shift the
transmission to neutral.
Pump rates and total volumes are digitally displayed on both the main
console and the Eco-Graph recorder display.
Fluid pick up and transfer is provided by 2- 2x3 hydraulic driven centrifugal
pumps. These are piped to work independently or in series using an
overboard fluid source or from the dual 10 barrel Stainless Steel
displacement tanks. These pumps can also pressurize the suctions for the
tri-plex pumps as needed.
Cement is mixed in an 8 barrel Stainless Steel averaging tank with a
Coriolis flow meter/ Densitometer. The slurry is re-circulated through the
mixer and Servo High Energy head with a hydraulic driven 5x6 centrifugal
pump and supported by a second 5x6 pump to pressurize the tri-plex
suctions or perform back-up mixing duties.